Quick Response QAC Test Strip

Quick Response QAC Test Strip

The Quick Response QAC Test strip (Quaternary Ammonium Compounds) is calibrated at 0, 100, 200, and 400ppm, and give a response in just one second.  This test strip can determine levels of up to 0-400ppm for many single, dual and 4-chain quat disinfectants to confirm their cleaning power is at full strength.

SKU: QAC-400 Categories: , , Tag:

Quick Response QAC Test Strip

  1. Dip the test strip into the solution to be tested for 1-2 seconds.
  2. Compare the test strip to the color chart within 10 seconds.

NOTE: These strips are guaranteed to accurately test: OASIS 146, Hyamine 35, Bardac 2250, Sysco (tablets).

qac test strip, qac test strips, qac, quick response qac, quick response qac test strip, quick response qac test strips, qac qr test strip

Precision Laboratories quat test papers and strips utilize an effect commonly referred to as the “protein-error of indicators” to quantify the QAC ppm levels.  While first observed with proteins (thus the name), the technique utilizes pH indicators and buffering systems to create an environment where the test paper or strip reacts (develops color) proportional to the amount of analyte (QAC) present.  The PL quat test papers and strips have color charts calibrated to solutions prepared from OASIS 146, an industry standard quat product.  The performance of the papers and strips with alternate quat products should always be verified.  In addition, any additives should be evaluated to see if they contribute to the “protein-error” effect.

QR050/S; QRD050; QR100/S; QRD100; QRG050; QRG100; QAC-400; QAC-400-1V-50; QAC-400-1V-100; QAC-400-1B-50; QAC-400-1B-100; QAC-400-12B-50; QAC-400-144B-50; QAC-400-144B-100

Product Specs

SKU 1:

QAC-400-1V-50 (1 vial, 50 strips/vial)

SKU 2:

QAC-400-1B-50 (1 bag, 50 strips/bag)

SKU 3:

QAC-400-1V-100 (1 vial, 100 strips/vial)

SKU 4:

QAC-400-1B-100 (1 bag, 100 strips/bag)

Strip Quantity:

100 strips, 50 strips

Bag Dimensions:

3" (W) x 4" (H) [76mm (W) x 102mm (H)] (Clear)

Vial Dimensions:

1.375″ (D) x 3.25″ (H) [35mm (D) x 83mm (H)]

Strip Dimensions:

2.5" (L) x .1875" (W) [64mm (L) x 5mm (W)]

Weight:

0.02 lbs [9.5 g] (50-strip bag), 0.04 lbs [18 g] (100-strip bag), 0.04 lbs [18.2 g] (50-strip vial), 0.05 lbs [25.7 g] (100-strip vial)

Shelf-Life:

2 Years

Label:

Customizable water-resistant label

Product Documentation

How are the ppm levels quantified on the QAC test strips?

Precision Laboratories QAC test papers and strips utilize an effect commonly referred to as the “protein-error of indicators” to quantify the QAC ppm levels. While first observed with proteins (thus the name), the technique utilizes pH indicators and buffering systems to create an environment where the test paper or strip reacts (develops color) proportional to the amount of analyte (QAC) present. The PL QAC test papers and strips have color charts calibrated to solutions prepared from OASIS 146, an industry standard QAC product. The performance of the papers and strips with alternate QAC products should always be verified. In addition, any additives should be evaluated to see if they contribute to the “protein-error” effect.

Can the QAC test strips be used to test a clean surface?

Can the Quick Response QAC (QAC-400) test strips be used to test clean surfaces by first dipping the strip in distilled water, and then pressing on a dry, cleaned food contact surface to obtain a result?

Answer: The QAC QR test strips and color chart were developed for use in water solutions, such as a three sink setup. They might detect qac residual on surfaces as described above, however, the color response won’t correlate to the color chart. The indicator in the test paper is fairly sensitive. It might work but it would need to be evaluated carefully.

Do you have a 1-second QAC test strip?

Yes! It’s called QAC QR5. Dip the test paper into the solution for 1 second, and wait 5-10 seconds before comparing to the color chart.

What are the dilution instructions for Quat (QAC) solutions?

Our test strips have been calibrated for use with all the commonly used hyamine and steramine quat (quaternary ammonium chloride) solutions. Some commercially available strips have errors as high as 50%. Use this guide to test your strips.

Oasis 146
To prepare a 400ppm QAC solution, dilute 0.530ml of Oasis 146 into 100ml of water.

Active IngredientsConc.Active IngredientsConc.
Alkyl dimethylbenzyl ammonium chloride3.00%Octyldecyl dimethyl ammonium chloride2.25%
di-n-octyl dimethyl ammonium chloride0.90%di-n-decyl dimethyl ammonium chloride1.35%

 

Hyamine 3500-80%
Prepare a stock solution by dissolving 1.25g in 100ml of water to produce a 10,000ppm solution. To prepare a 400ppm QAC solution, dilute 4ml of the stock solution into 100ml of water.

Active Ingredients
n-Alkyl (C14=50%, C12=40%, C16=10%) dimethylbenzyl ammonium chloride-80%

 

Bardac 2280
Prepare a stock solution by dissolving 1.25g Bardac 2280 in 100ml of water to produce a 10,000ppm solution. To prepare a 400ppm QAC solution, dilute 4ml of the stock solution into 100ml of water.

Active Ingredients
Didecyldimethyl ammonium chloride-80%

 

Bardac 2250
Prepare a stock solution by dissolving 2g Bardac 2250 in 100ml of water to produce a 10,000ppm solution. To prepare a 400ppm QAC solution, dilute 4ml of the stock solution into 100ml of water.

Active Ingredients
Didecyldimethyl ammonium chloride-50%

 

Sysco QAC Tablets
To prepare a 400ppm QAC solution, place 1 tablet into 2.82L (1 US Gal.) of water.

Active Ingredients
Alkyl (C14=95%, C12=3%, C16=2%) dimethylbenzyl ammonium chloride-50%

Does the accuracy of QAC test strips depend on the pH of the solution?

The accuracy of QAC tests strips does not depend on the pH value of solutions to be tested in the range of 1.86 – 9.2 pH, but rather it depends on buffering capacity. When the pH of a solution to be tested is a result of acidic or alkaline compounds without buffering capacity, then the accuracy of the test is not influenced. In the case that the pH of a solution to be tested is a result of a buffer, then the measure of influence depends on the buffering capacity of the solution.

Test:
Sets of control solutions with QAC concentrations 0 – 50 – 100 – 200 – 400 ppm were prepared in following solutions:

  • Hydrochloric acid /0.1 M/, pH 1.1
  • Tartaric acid /0.1M/ , pH 1.86
  • McIlvaine buffers (0.1M citric acid, 0.2 M  disodium hydrogen  phosphate), pH 2.2 – 3.0 – 4.0 – 5.0 – 6.0 – 7.0 – 8.0 – 9.0
  • Sodium tetraborate /0.01M/ , 9.20

The table below contains readings according to the regular color chart:

    pH buffer  /b/ 0 ppm QAC  50 ppm QAC 100 ppm QAC 200 ppm QAC 400ppm QAC
    1.1      0      0      0    ≤50     50
    1.86      0     50    100    200    400
    2.2  /b/      0   0-50      50    100    200
    3.0  /b/      0     50    100    200    400
    4.0  /b/      0     50    100    200    400
    5.0  /b/    ≤ 50    100    200    400   ≥400
    6.0  /b/     50    200    400  higher higher
    7.0  /b/    100    400    ≥400  higher higher
    8.0  /b/    200    400    higher  higher higher
    9.0  /b/    400   higher    higher  higher higher
    9.2      0      50     100    200    400

Does temperature affect QAC test strip results?

Higher temps:

Testing was run on set of control solutions 0 – 50 – 100 – 200 – 400 ppm Hyamine 1622 (Fluka) warmed up to temperatures in the range 35 – 60oC.

T (oC)QAC strips reading in control solutions 0 – 50 – 100 – 200 – 400 ppm
35reading OK in the whole concentration range
40reading OK in the whole concentration range
450 – 50 - 100 ppm OK, 200 and 400 ppm reading cca half color square higher
5050 – 100 ppm reading cca half color square higher, 200 – 400 ppm reading 1 color square higher
55reading 1 color square higher in the whole range
60reading 1 color square higher in the whole range

Lower temps:

Testing was run on a set of control solutions at 100, 200, 300, and 400 ppm QAC using Oasis 146 stock.

The samples were split, so that one set was kept at room temp (76F) and one set was placed into the refrigerator (38F).  Both the paper strips (SKU: 106) and the plastic backed test pads (SKU: QAC-400) were tested.  The test papers showed no visual difference at any of the concentrations.  The plastic backed strips did not show any visual difference, with the exception of the 100 ppm standard. The refrigerated standard read slightly lower (maybe ¼-½ a color unit, read as 50-75 ppm). The test was repeated several times and these results were confirmed.